6GK7542-5FX00-0XE0 Communication Processor CP 1542-5, Used To Connect SIMATIC S7-1500 To PROFIBUS-DP

Hunan Shengke Automation Technology Co., Ltd.
Contact Now

6GK7542-5FX00-0XE0 Communication Processor CP 1542-5, Used To Connect SIMATIC S7-1500 To PROFIBUS-DP

Brand Name : Siemens

Model Number : 6GK7542-5FX00-0XE0

Certification : CE

Place of Origin : Germany

MOQ : 1 pcs

Price : $400-$450

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 1000

Delivery Time : 1-3 days

Packaging Details : Original Packing

Product Name : CP 1542-5

Condition : Original

Leading Time : 3-5 DAYS

Warranty : ONE-Year

Type : PLC

Contact Now

6GK7542-5FX00-0XE0 Communication Processor CP 1542-5, Used To Connect SIMATIC S7-1500 To PROFIBUS-DP
6GK7542-5FX00-0XE0 is a communication module from Siemens, and its detailed introduction is as follows:

1. Basic information:
• Series: Belonging to the communication module series of Siemens S7-1500 PLC, it is an important component used to expand the communication capability of S7-1500 control system.
• Product number meaning: "6GK7" is a specific identifier for Siemens communication modules; 542 "represents the specific model series of the module; 5FX00 "is the specific function and feature code of the product; 0XE0 "is the version or other specific identification information of the product.
2. Performance parameters:
Communication protocol: Supports PROFIBUS DP communication protocol and complies with IEC 61158/61784 standard. As the DP-V1 master station, it can perform data transmission completely independently and allows connection to up to 32 slave stations, such as CM1242-5 (as a DP slave station), DP slave stations of ET200 distributed I/O system, etc. This enables the S7-1500 station to easily communicate with other devices in the PROFIBUS-DP network, making it ideal for expanding the integrated DP master interface of the S7-1500 CPU (CPU1516 and higher models) to establish other PROFIBUS-DP buses.
• Transmission rate: The transmission rate complies with PROFIBUS at the interface, ranging from 9.6 kbit/s to 12 Mbit/s, which can meet the communication speed requirements of different application scenarios.
• Data processing capability: With fast data processing capabilities, it can efficiently transmit and process large amounts of communication data, ensuring real-time and accurate communication. Regardless of the system size, the response time of this module is relatively short.
3. Functional features:
• Synchronization and Freeze Function: Users can use the DPSYNC_FR system function from the user program to synchronize (Sync/Freeze) the output or input, making it convenient for users to control and manage the communication process.
Programmer/OP communication: Supports programmer/OP communication, and all S7 stations connected to the network can be remotely programmed, making it convenient for users to debug and maintain programs. At the same time, with the help of routing, programming devices can also be used to communicate across networks, improving the flexibility and scalability of the system.
Time synchronization: It can transfer time from S7-1500 CPU to PROFIBUS and provide the current time on PROFIBUS to achieve clock synchronization throughout the factory, which is very important for industrial automation systems that require time synchronization.
Diagnostic function: TIAPortal V12 SP1 or higher version STEP7 Professional provides a large number of diagnostic functions, including the status of communication processors, general diagnostic and statistical functions, connection diagnosis, bus statistics, alarm buffers, etc. In addition, the module also supports diagnosing the operation of the relay, which can diagnose the line during operation and detect line faults at an earlier stage.
4. Electrical characteristics:
• Power supply voltage: The power supply voltage type is DC, from the backplane bus, with a voltage of 15V and a relative symmetrical tolerance of 3% when in DC.
• Current consumption: When the current consumption comes from the backplane bus DC, the typical value is 0.1A, and the power loss is 1.5W.
5. Environmental adaptability:
• Temperature range: The ambient temperature during vertical installation is 0 ° C to 40 ° C, and during horizontal installation it is 0 ° C to 60 ° C; The temperature range during storage and transportation is -40 ° C to+70 ° C, which can adapt to different working environment temperature requirements.
Relative humidity: The maximum relative air humidity during non condensing operation at 25 ° C is 95%, which has a certain degree of moisture resistance.
• Protection level: The protection level is IP20, which can prevent dust and other foreign objects from entering the interior of the module, but does not have waterproof function.

China 6GK7542-5FX00-0XE0 Communication Processor CP 1542-5, Used To Connect SIMATIC S7-1500 To PROFIBUS-DP factory

6GK7542-5FX00-0XE0 Communication Processor CP 1542-5, Used To Connect SIMATIC S7-1500 To PROFIBUS-DP Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hunan Shengke Automation Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)